Backflow information
Backflow prevention protects your drinking water from contamination, and every irrigation system needs it. Here’s how it works and how EZ-FLO meets the requirements.
What is backflow?
The American Backflow Prevention Association defines backflow as the undesirable reversal of water flow through a cross-connection into your drinking water system. Two types can occur in irrigation systems: backpressure backflow and backsiphonage.
Almost all local plumbing codes require irrigation systems to have a proper backflow prevention device. In most places it’s the law.
Important requirement
Every EZ-FLO installation needs an appropriate backflow prevention device: main-line, hose-end and drip systems alike. Follow your local plumbing codes. If a contractor says backflow protection isn’t needed, find another contractor.
Two types of backflow
Knowing both helps you choose the right protection.
Backpressure backflow
Happens when downstream pressure exceeds the supply pressure, forcing non-potable water back into the drinking water system. Causes include pumps creating extra pressure, thermal expansion in closed systems, or elevation changes where irrigation zones sit higher than the water source.
Common causes
- Pumps creating higher downstream pressure
- Temperature increases in boilers
- Irrigation zones higher than the PVB
- Supply pressure drops during high demand
Backsiphonage
Occurs when a vacuum develops in the supply line, like drinking through a straw, pulling contaminated water backward into clean lines.
Common causes
- Nearby firefighting
- Water main breaks
- Water line flushing
- Sudden stoppage of water supply

The backflow preventer goes before the EZ-FLO
In a protected system, the backflow device always sits between your water supply and the EZ-FLO unit.
- The pressure vacuum breaker protects the water supply
- The EZ-FLO tank installs after the backflow preventer
- Zone valves control the irrigation areas downstream
Backflow prevention devices
Several types work with irrigation, but only specific types should be used with fertigation.
- Reduced pressure zone (RPZ) Two spring-loaded check valves with a pressure differential relief valve between them. Shutoff valves and test cocks on each end allow annual testing. The highest level of protection, against both backpressure and backsiphonage. Backpressure protectionBacksiphonage protectionHealth and non-health hazards
- Pressure vacuum breaker (PVB) A spring-loaded check valve and a spring-loaded air inlet valve on the discharge side. Protects against backsiphonage only, and must be installed at least 12 inches above the highest sprinkler head or emitter. Backsiphonage onlyHealth and non-health hazards
- Anti-siphon valve For hose-end EZ-FLO units on outdoor faucets, the minimum requirement is an anti-siphon valve upstream of the connection point. Many hose bibs have one built in, so check yours before installing. Hose bib systems onlyMinimum requirement
Extra protection engineered into EZ-FLO
Even if backflow occurred and your primary device failed, these safeguards minimize risk.
- Air-lock designEZ-FLO units air-lock when flow reverses, which stops proportioning and prevents significant contamination.
- 1/8 tsp maximum exposureIf reverse flow occurred, at most 1/8 teaspoon of fertilizer could enter the inlet side before the unit stops proportioning.
- High dilution ratioMain-line units proportion from 400:1 (fast) to 15,000:1 (slow), so any backflow would be extremely diluted.
Reviewed by a national standards body
We submitted our fertigation system to the University of Southern California’s Foundation for Cross-Connection Control and Hydraulic Research, which tests and certifies backflow prevention devices. Every major manufacturer in the industry submits its products there for approval.
In May 2004 the Foundation classified EZ-FLO systems as aspiration devices, not injection devices. EZ-FLO operates under ambient water pressure and cannot add backpressure to the system. The minimum acceptable backflow device is a pressure vacuum breaker (PVB); reduced pressure zone (RP) assemblies are also acceptable and required by some local codes.
Unlike mechanical injectors or pumps, EZ-FLO uses differential pressure within a closed loop. No moving parts, no motors, and no added pressure.
Questions about your installation?
Our team can help you check your backflow setup before you install.